W6 Chemical
W6 Chemical

High purity product and low energy consumption are key properties of the melt crystallization process. The efficiency of chemical purification operations can be increased through crystallization. GEA Niro PT has several pilot units available (Download our brochure) to demonstrate the feasibility of our crystallization process on a wide range of chemicals. Some successful applications with melting points from -45°C to over 130°C include:

A selection of tested chemicals

Product

Formula

CAS no.

Mol. Wt.
g/mol

Tmelt
°C

Benzoic acid C7H6O2 65-85-0 122.12

122.40

L-Lactide C6H8O4 4511-42-6

144.13

98.70

p-Nitrochlorobenzene C6H4NO2Cl 100-00-5

157.56

82.50

Durene (tetramethylbenzene) C10H14 95-93-2

134.22

79.24

Caprolactam C6H11NO

105-60-2

113.60

69.20

Mono chloroacetic acid (MCA) C2H3ClO2

79-11-8

94.49

61.18

o-Phenylphenol (OPP) C12H10O

90-43-7

170.21

57.45

p-Dichlorobenzene C6H4Cl2

106-46-7

147.00

53.10

Maleic anhydride C4H2O3

108-31-6

98.05

52.00

MDI - 4,4

C15H10N2O2

101-68-8

250.25

40.42

Dicyclopentadiene

C10H12

77-73-6

132.20

32.00

Phosphoric Acid (hemi-hydrate) H3PO4-½H2O

7664-38-2

107.00

29.30

ToluenediIsocyanate (2,4 TDI) C9H6N2O2

584-84-9

174.16

21.80

Methacrylic acid C4H6O2

79-41-4

86.09

14.35

Acrylic acid C3H4O2

79-10-7

72.06

13.50

N-vinyl-2-pyrrolidone (NVP) C6H9NO

88-12-0

111.14

13.50

p-Xylene C8H10

106-42-3

106.17

13.26

p-Chlorotoluene C7H7Cl

106-43-4

126.58

7.55

γ-picoline C6H7N

108-89-4

93.13

3.65

Hydrogen Peroxide H2O2

7722-84-1

34.01

-0.40

Ethyl lactate (S) C5H10O3

687-47-8

118.13

-2.70

Acetonitrile C2H3N

75-05-8

41.05

-44.50

m-Xylene C8H10

108-38-3

106.17

-47.87

For more info download our brochure 

W6-Chemical
The standard pilot plant for new applications of melt crystallization. The W6-C is suitable for all chemical applications with melting points from +150°C to -60°C. Test work can be completed at GEA Niro’s


W6 for chemical applicationspremises in The Netherlands or if required can be shipped anywhere in the world. The unit is completely self-contained, requires only standard utilities (electricity, compressed air and cooling water), explosion proof (ATEX II3G IIB T2) and can therefore be installed in most industrial locations.


W6-3
Our standard freeze concentration unit but used exclusively for the chemical waste water applications. This unit is configured for applications with industrial waste water. Chemical waste water may be difficult to ship to us as it is typically considered a hazardous product. This skid unit is also self-contained and can be easily installed on-site in just a few hours. It includes options to allow testing different equipment configurations. The data collected from a test run can be used to accurately design a full scale industrial unit.

W60
Wash column / Continuous wash column separation unit available for connection to existing


W60 Washcolumn for chemical applicationscrystallization systems. The W60 wash column is not a self-contained unit but can be installed slip-stream to an existing crystallizer. The results of a test run can be used to compare the efficiency of wash column separation with the existing centrifuge or filtration system.

Please contact us for a detailed test proposal for any of the above mentioned units





Download brochure in PDF-format
Click anywhere in this box to view and/or download the brochure in Adobe PDF format.